variable refrigerant flow : ウィキペディア英語版
variable refrigerant flow
Variable refrigerant flow (VRF) is an HVAC technology invented in Japan by Daikin company in 1982.〔 Like ductless minisplits VRFs use refrigerant as the cooling and heating medium. This refrigerant is conditioned by a single outdoor condensing unit, and is circulated within the building to multiple fan-coil units (FCUs).
==Description==
VRFs are typically installed with an Air conditioner inverter which adds a DC inverter to the compressor in order to support variable motor speed and thus variable refrigerant flow rather than simply on/off operation. By operating at varying speeds, VRF units work only at the needed rate allowing for substantial energy savings at partial-load conditions. Heat recovery VRF technology allows individual indoor units to heat or cool as required, while the compressor load benefits from the internal heat recovery. Energy savings of up to 55% are predicted over comparable unitary equipment.〔

This also results in greater control of the building's interior temperature by the building's occupants.
VRFs come in two system formats, two pipe and three pipe systems. In a heat pump 2 pipe system all of the zones must either be all in cooling or all in heating. Heat Recovery (HR) systems have the ability to simultaneously heat certain zones while cooling others; this is usually done through a 3 pipe design, with the exception of Mitsubishi which is able to do this with 2 pipes. In this case the heat extracted from zones requiring cooling is put to use in the zones requiring heating. This is made possible because the heating unit is functioning as a condenser, providing sub-cooled liquid back into the line that is being used for cooling. While the heat recovery system has a greater initial cost, it allows for better zoned thermal control of a building and overall greater efficiencies.〔Goetzler. (2007, April). Variable Refrigerant Flow Systems. ASHRAE Journal: 24-31.〕

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「variable refrigerant flow」の詳細全文を読む